A cutting-edge facility for the analysis of C, N, O and H isotopes in environmental samples
The Skidaway Institute Scientific Stable Isotope Laboratory (SISSIL) is able to analyze an extremely wide range of environmental samples — a capability matched by no other lab in the Southeast. The Lab consists of
2 state of the art light stable isotope mass spectrometers with 5 interfaces, microbalance, hoods and other support equipment for sample preparation. Guest scientists and students are welcome to visit Skidaway and see firsthand this facility, and hands-on training is both possible and encouraged for larger projects.
One IRMS instrument is configured to analyze solid samples such as soils, liquids such as water, and volatile samples like hydrocarbons with a gas chromatograph. There is also a conventional Hewlett-Packard GC/MS for quantification and purity validation.
The second instrument (New in 2024) has a complementary set of interfaces designed to measure the carbon isotopic composition of inorganic carbon and non-volatile organic compounds by HPLC, as well as very small amounts of C, N and S in solid samples (a nano-Elemental analyzer). A method developed by Brandes allows for the rapid (<12 minutes, including prep) analysis of dissolved inorganic carbon in any water matrix at very high (~0.05 per mil) precision. This capability has been used to investigate the photochemical reactivity of dissolved organic matter and carbon biogeochemistry within sediments.
The Skidaway Institute is surrounded by outdoor, natural laboratories, such as salt marshes, estuaries and the coastal ocean. Having the SISSIL facility located on our campus furnishes collaborating researchers and students with instant feedback on experimental results during their field studies. We have had many such successful collaborations with students from Savannah State, Georgia Southern, College of Charleston, and others.
Mass spec #1: Delta V plus (2007) Instrument has 2 interfaces:
1. Flash 1112 EA for analysis of solid C, N isotopes. Types of samples: soils, sediments, plants, animal tissue, and particulates on filters. 2. Trace GC with Split/Splitless injectors and cool-on-column injector. System has both combustion (15N, 13C) and pyrolysis (H/D) furnaces. Used to measure isotopic composition of individual compounds separated by gas chromatography. |
Mass spec #2: Delta V plus (2024)
Instrument has 2 interfaces plus Dual inlet for gas analyses: 1. Isolink II LC-C-IRMS interface for the 13C analysis of DOC, DIC and organic compounds in aqueous solutions. Interface has quaternary mixing pump, Autosampler and manual injection modes. 2. Elemental analyzer+Gas bench with cold finger preconcentrator. System configured to analyze sub- micromole amounts of C, N and S for content and stable isotope composition in solid samples. |